Certificate PL-26-00301 · Semax 1 mg/mL Pen · lot PL-2610-188
VerifyCertificate page
PrymaLab
PrymaLab
PrymaLab Analytical · In-house laboratory
3705 Music Branch Rd, Ashland, KY 41102 · +1 (606) 465-9063 · prymalab.net
Certificate no.
PL-26-00301
Verification key
JHMGSEQY
Scan or enter both at
prymalab.net/testing/verify

Certificate of Analysis · Lot release

Semax 1 mg/mL Pen

Lot PL-2610-188 · Solution · Label claim 1 mg/mL
Tested in-house by PrymaLab
In-house analytical result,
not an independent third-party test
Lot / batch number
PL-2610-188
Date made
2026-10-07
Date of analysis
2026-10-08
Date issued
2026-10-22
Retest / expiry
2028-10-07
Units in lot / sampled
380 / 2
Storage
—
Certificate type
Lot COA, 2 pages
Compound
Semax
ACTH(4–7)-Pro-Gly-Pro heptapeptide (MEHFPGP)
CAS number
80714-61-0
Molecular formula
C37H51N9O10S
Theoretical mass (avg.)
813.90 Da
Sequence
MEHFPGP
Purity · RP-HPLC, area %
99.70%
Specification ≥ 99.0% • main peak at 10.63 min
Identity · Observed Mass
813.91 Da
Theoretical 813.90 Da • +0.01 Da (12 ppm)
Overall conclusion
PASS
Meets every specification for the tests performed
TestMethodSpecificationResultConclusion
Identity (mass)LC-MS, ESI positiveTheoretical ± 1.0 Da813.91 DaPASS
PurityRP-HPLC, UV 214 nm, area%≥ 99.0%99.70%PASS
Largest impurityRP-HPLC, area%≤ 1.0%0.15% (RT 12.10)PASS
Assay (label claim)Assay vs label claim0.95–1.05 mg/mL1.02 mg/mLPASS
Bacterial endotoxinLAL, kinetic≤ 5.0 EU/mg0.401 EU/mgPASS
SterilityUSP <71>, 14-dayNo growthNo growthPASS

1HPLC chromatogram

Data file: PL-2610-188-HPLC.raw · Column C18, 150 × 4.6 mm · UV 214 nm
0.01%0.1%1%10%100%891011121314Retention time (min) · stick height = area % (log scale)99.70% · 10.63 min0.09% †0.06% †0.15% †
Peak plot drawn from the integrated peak table (area %, log scale); it is not the instrument trace, which is retained in PL-2610-188-HPLC.raw. † Nominal reference retention time for the assigned impurity; the main-peak RT is observed in this lot.
PrymaLab
PrymaLab
Certificate of Analysis · continued
Semax 1 mg/mL Pen · Lot PL-2610-188 · Certificate PL-26-00301
Lot PL-2610-188
Method, peak table and approval

2HPLC method · PL-2610-188-HPLC.raw

Instrument
Waters Alliance e2695
Data System
Empower 3
Detector
UV absorbance
Detection Wavelength
214 nm
Column
C18, 150 × 4.6 mm, 3.5 µm
Mobile Phase A
0.1% TFA in water
Mobile Phase B
0.1% TFA in MeCN
Gradient
5–95% B over 25 min (linear)
Flow Rate
1.0 mL/min
Column Temperature
40 °C
Injection Volume
10 µL

3Gradient program

Time (min)% A% B
0.0955
25.0595

4Peak table

PeakRT (min)AreaArea %
19.50 †—0.09
210.63—99.70
311.40 †—0.06
412.10 †—0.15
Total—100.00
Peaks: 1 methionine oxidation product; 2 main peak (Semax); 3 deamidation product; 4 truncated sequence · Area % from the integrated peak table (absolute areas are not part of the lot-release export) · † nominal reference RT for the assigned impurity · Purity = main peak area ÷ total integrated area × 100, to two decimals; main peak shaded.

5Identity by mass spectrometry

Instrument
Waters SQD
Ionization / Mode
ESI, positive
Reference m/z (charge)
814.91 (M+H)+
Deconvoluted Mass
813.91 Da
Theoretical Mass
813.90 Da
Difference
+0.01 Da (12 ppm)
Data File
PL-2610-188-MS.d
Acceptance
Within ± 1.0 Da

6Additional tests

TestPerformed byDateReport / file
Assay vs label claimPrymaLab Analytical2026-10-08—
Endotoxin (LAL, kinetic)PrymaLab Analytical2026-10-08—
Sterility (USP <71>, day-14 read-out)PrymaLab Analytical2026-10-22—
A test with no row here was not performed on this lot. Outside-laboratory reports, when used, are attached and named below.

7Review and approval

D. Reynolds
Analyst · performed the testing
Date: 2026-10-22
S. Calloway
Reviewer · checked against raw data
Date: 2026-10-22
M. Phelps
Lab Director · approved for release