Certificate of Analysis · Lot release · Issued for Epic Wholesalers LLC -dba-Epic Peptides Lab
MK-677 10 mg Capsules (60 ct)
Lot PL-2610-128 · Capsules · Label claim 10 mg per capsule
Tested in-house by PrymaLab
In-house analytical result, not an independent third-party test
Lot / batch number
PL-2610-128
Date made
2026-10-05
Date of analysis
2026-10-06
Date issued
2026-10-13
Retest / expiry
2028-10-05
Units in lot / sampled
252 / 2
Storage
—
Certificate type
Lot COA, 2 pages
Compound
MK-677
CAS number
159752-10-0
Molecular formula
free base C27H36N4O5S
Theoretical mass (avg.)
528.66 Da
Structure
Purity · RP-HPLC, area %
99.89%
Specification ≥ 99.0% • main peak at 12.86 min
Identity · Observed Mass
528.67 Da
Theoretical 528.66 Da • +0.01 Da (19 ppm)
Overall conclusion
PASS
Meets every specification for the tests performed
Test
Method
Specification
Result
Conclusion
Identity (mass)
LC-MS, ESI positive
Theoretical ± 1.0 Da
528.67 Da
PASS
Purity
RP-HPLC, UV 254–306 nm, area%
≥ 99.0%
99.89%
PASS
Largest impurity
RP-HPLC, area%
≤ 1.0%
0.05% (RT 11.60)
PASS
Capsule content
Content vs label claim
9–11 mg/cap
9.91 mg/cap
PASS
Bacterial endotoxin
LAL, kinetic
—
—
N/A
Aerobic count (TAMC)
USP <61>
< 10 CFU/g
< 10 CFU/g
PASS
Yeast & mold (TYMC)
USP <61>
< 10 CFU/g
< 10 CFU/g
PASS
E. coli
USP <62>
Absent
Absent
PASS
1HPLC chromatogram
Data file: PL-2610-128-HPLC.raw · Column C18, 150 × 4.6 mm · UV 254–306 nm
Peak plot drawn from the integrated peak table (area %, log scale); it is not the instrument trace, which is retained in PL-2610-128-HPLC.raw. † Nominal reference retention time for the assigned impurity; the main-peak RT is observed in this lot.
Peaks: 1 unidentified impurity; 2 main peak (MK-677); 3 unidentified impurity; 4 unidentified impurity · Area % from the integrated peak table (absolute areas are not part of the lot-release export) · † nominal reference RT for the assigned impurity · Purity = main peak area ÷ total integrated area × 100, to two decimals; main peak shaded.
5Identity by mass spectrometry
Instrument
Waters SQD
Ionization / Mode
ESI, positive
Reference m/z (ion)
529.67 [M+H]+
Deconvoluted Mass
528.67 Da
Theoretical Mass
528.66 Da
Difference
+0.01 Da (19 ppm)
Data File
PL-2610-128-MS.d
Acceptance
Within ± 1.0 Da
6Additional tests
Test
Performed by
Date
Report / file
Content vs label claim
PrymaLab Analytical
2026-10-06
—
Microbial limits (USP <61>/<62>)
PrymaLab Analytical
2026-10-12
—
A test with no row here was not performed on this lot. Outside-laboratory reports, when used, are attached and named below.
7Review and approval
D. Reynolds Analyst · performed the testing Date: 2026-10-13
S. Calloway Reviewer · checked against raw data Date: 2026-10-13
M. Phelps Lab Director · approved for release Date: 2026-10-13