Certificate of Analysis · Lot release
CJC-1295 (no DAC) 5 mg
Lot PL-2609-022 · Lyophilized powder · Label claim 5 mg/vial
Tested in-house by PrymaLabIn-house analytical result,
not an independent third-party test
Lot / batch number
PL-2609-022
Date of analysis
2026-09-19
Retest / expiry
2028-09-18
Units in lot / sampled
250 / 2
Storage
−20 °C, desiccated, dark
Certificate type
Lot COA, 2 pages
Compound
CJC-1295 (no DAC)
Modified GRF (1-29); tetrasubstituted GHRH(1–29) analogue (D-Ala2, Gln8, Ala15, Leu27)
Molecular formula
C152H252N44O42
Theoretical mass (avg.)
3367.9 Da
Sequence
H-Y-[D-Ala]-DAIFTQSYRKVLAQLSARKLLQDILSR-NH₂ (29 residues; C-terminal amide)
Purity · RP-HPLC, area %
99.70%
Specification 99.0% • main peak at 6.38 min
Identity · Observed Mass
3368.1 Da
Theoretical 3367.9 Da • +0.2 Da (59 ppm)
Overall conclusion
PASS
Meets every specification for the tests performed
| Test | Method | Specification | Result | Conclusion |
| Appearance | Visual inspection | White to off-white lyophilized powder | White lyophilized powder | PASS |
| Identity (mass) | LC-MS, ESI positive | Theoretical ± 1.0 Da | 3368.1 Da | PASS |
| Purity | RP-HPLC, UV 214 nm, area% | 99.0% | 99.70% | PASS |
| Largest impurity | RP-HPLC, area% | 1.0% | 0.12% at 6.91 min | PASS |
| Water content | Karl Fischer | 5.0% | 1.6% | PASS |
| Bacterial endotoxin | LAL, kinetic | ≤ 5.0 EU/mg | 0.05 EU/mg | PASS |
| Sterility / bioburden | USP <71>, membrane filtration | No growth after 14 days | No growth; conforms | PASS |
1HPLC chromatogram
Data file: CJC_PL-2609-022_20260919_01 · Column C18, 150 × 4.6 mm · UV 214 nm
Baseline uncropped; main peak and impurities labeled with retention times. Peak table on page 2.
2HPLC method · CJC_PL-2609-022_20260919_01
Instrument
Waters Alliance e2695, SN E2695B742
Data System
Empower 3, Build 3471
Detection Wavelength
214 nm
Column
C18, 150 × 4.6 mm, 3.5 µm
Column Part / Serial
186003326 / USHX18211
Mobile Phase A
0.1% TFA in water
Mobile Phase B
0.1% TFA in MeCN
Sample Diluent
Water, 0.1% TFA
Sample Concentration
0.5 mg/mL
Reference Standard
In-house CJC-1295 (No DAC) reference, lot PL-RS-CJC-01, RT 6.36 min
3Gradient program
| Time (min) | % A | % B |
| 0.0 | 95 | 5 |
| 3.0 | 95 | 5 |
| 7.0 | 55 | 45 |
| 8.0 | 20 | 80 |
| 9.0 | 20 | 80 |
| 10.0 | 95 | 5 |
4Peak table
| Peak | RT (min) | Area | Area % |
| 1 | 6.38 | 4,287,100 | 99.70 |
| 2 | 6.91 | 5,160 | 0.12 |
| 3 | 7.38 | 4,300 | 0.10 |
| 4 | 8.04 | 3,440 | 0.08 |
| Total | | 4,300,000 | 100.00 |
Threshold 0.05% area · Blank subtracted: Y · Purity = main peak area ÷ total integrated area × 100, to two decimals; main peak shaded.
5Identity by mass spectrometry
Instrument
Waters Acquity SQD
Ionization / Mode
ESI, positive
Observed m/z (charge)
1123.7 (3+ [M+3H]) · 843.0 (4+ [M+4H])
Deconvoluted Mass
3368.1 Da
Theoretical Mass
3367.9 Da
Difference
+0.2 Da (59 ppm)
Data File
CJC_PL-2609-022_MS_20260919_01
Acceptance
Within ± 1.0 Da
6Additional tests
| Test | Performed by | Date | Report / file |
| Water content | PrymaLab | 2026-09-20 | RPT-KF-PL-2609-022 |
| Endotoxin | PrymaLab | 2026-09-21 | RPT-ET-PL-2609-022 |
| Sterility | PrymaLab | 2026-10-02 | RPT-ST-PL-2609-022 |
A test with no row here was not performed on this lot. Outside-laboratory reports, when used, are attached and named below.
7Review and approval
D. Reynolds
Analyst · performed the testing
Date: 2026-09-19
S. Calloway
Reviewer · checked against raw data
Date: 2026-10-02
M. Phelps
Lab Director · approved for release
Date: 2026-10-03